Fire hose volumes - Fire Engineering Training Community

2009/5/23· NFPA 1901 says all 2.5" discharges must flow at least 250 gpm at 150 psi, but do not limit the flow. You can have your pumper piped any way you like as long as you hit the minimums. Point being, you can flow 250 gpm through a 1.5" line off the right discharge.

Pex Sizes Gpm - befasr

There is 2.31 feet of water per 1 psi. There for at 8 gpm, 1'' pex, 240 feet of pipe, 9 elbows or tees equals 330 equivelant length of pipe. 330 x 0.041 x 2.31 = 31.25 feet of loss. This doesn''t include boiler losses or other accessories. A flow control valve adds 1 foot of

Diaphragm Water Pump - 1.0 GPM 40 psi SEAFLO Pump

The SEAFLO 1.0 GPM 40 psi On Demand Diaphragm Water Pump 12V are compact self-priming pumps designed for liquid transfer, marine,boat,yacht, and automatic demand water systems. SEAFLO 21 Series DC Diaphragm Pump 12V/24V 2.0-4.3LPM 17-80PSI

Flow Capacities for fire hose - Firehouse Forums - …

2008/5/11· That is 50 psi for overcoming the friction loss in the hose and 100 psi to properly operate the nozzle. When sending water through a 2 1/2" line at 100 gpm it takes about 2 1/2 psi per 100 ft. of hose. At the same flow rate, 500 ft. of hose will require 13 psi to move

HANDLINE Flow & Nozzle Reaction Chart - TFT

FLOW (GPM) REACTION (LBS) 100 PSI = 100 PSI HANDLINE 75 PSI = 75 PSI HANDLINE 250 150 ft.200 ft.250 ft. 2-1/2" HOSE PUMP DISCHARGE PRESSURE (PSI) 100 PSI 75 PSI 75 PSI100 PSI 100 PSI 47 59 85 100 126 142 165 185 201 16 25 42 50 55

Fire hose volumes - Fire Engineering Training Community

2009/5/23· NFPA 1901 says all 2.5" discharges must flow at least 250 gpm at 150 psi, but do not limit the flow. You can have your pumper piped any way you like as long as you hit the minimums. Point being, you can flow 250 gpm through a 1.5" line off the right discharge.

Converting Gallon per Minute to PSI - Pipe Flow …

2013/4/11· Hi, I was wondering what the equations were for converting gallons per minute into pounds per square inch. The diameter of the pipe being used is 1" (standard garden hose). These is no elevation change and the pumping distance is negligible (under 2 ft). Any

How Much Water Does A Pressure Washer Use? (GPM …

So, in addition to PSI, you need to compare GPM as well. They work together to get things clean. Let’s assume a Sun Joe XPX 3000 pressure washer with 1.76 GPM and 2030 PSI competes with Stanley SHP2150 pressure washer with 1.4 GPM with 2150 PSI.

Flow Rate Calculator - Pressure and Diameter | Copely

Our Flow Rate Calculator will calculate the average flow rate of fluids based on the bore diameter, pressure and length of the hose. The effects on the predicted water flow are then given in three graphs where in turn two of the variables are kept constant.

CALCULATING FLOW RATES – HoseMonster

QR = Flow-rate predicted at the desired residual pressure in GPM QF = Total test flow-rate measured during test in GPM (GPM measured from Hose Monster or Pitotless Nozzle) HR = Pressure drop from static pressure to desired residual pressure (Static – 20 psi [if 20 psi is the desired residual pressure])

Pitot Gauges: How Do I Calculate the PSI to GPM …

Step 5: Multiply the final two nuers to solve for Q, the discharge in GPM. 174.6 x 7.8740 = 1,375 GPM Now that you’ve got a grasp on how PSI, discharge coefficients, and diameter impact a hydrant’s flow rates, try our handy GPM calculator for fire hydrants:

Hydraulic Hose Sizing - Open Source Ecology

The 50 hp Volkswagen engine is believed to deliver the peak torque at 2700 RPM (needs confirmation) This increased fluid flow requires quick couplers capable of handling more flow. This coupler is rated for 26.4 GPM:

Hose pressure loss

For instance, 50 FT of hose will have 1/2 of the amount of loss and 200 FT of hose will have double the loss of the amount shown in the chart. There are several other factors that may cause pressure loss such as hose liner ID tolerance, hose inner liner smoothness, manner in which the hose is laid out during use, type of fittings on each end, and sometimes the temperature of the water.

The Interior Attack Line: Getting the Most Bang for …

2014/8/29· Based on a 240-gpm flow, FL in this hose is between 60 and 70 psi per 100 feet. Keep in mind that these nuers are only approximate. To come up with exact nuers, it is important to do flow tests on the hose your department uses.

Flow Rate to PSI Calculator

Flow Rate to PSI Calculator A classical physics calculator to convert flow rate of a liquid to PSI, the pressure. Flow rate, a term in fluid dynamics and hydrometry, is the volume of fluid which passes through a container (example: a pipe) per unit time and is

Garden Hose Flow Calculator

Garden Hose Flow - US Gallons Results: Water Flow gpm Calculation select hose diameter and available source pressure select a hose length Result amount of water flowing from the end of the hose in US gallons per min Garden Hose Water Flow - Inperial

Flow Chart

FM Approved FLOWBUSTER TM FLOW CHART For a given Pitot pressure in PSI, this Flow Chart will determine your Flow in GPM for the specific Nozzle diameter used. Please contact us if you need values for pressures other than those shown. PSI 1-1/8" 1

4.13 Sprinkler & Standpipe Flow Rate and Required …

Therefore, the minimum hose valve outlet pressure at 250 gpm total standpipe flow is 100 psi, and the minimum hose valve outlet pressure at the maximum standpipe flow is 75 psi.

GPM/GPH Flow based on PVC Pipe Size

Pressure Flow in GPM through pipe ID in inches PSI 1" 1.25" 1.5" 2" 2.5" 3" 4" 5" 20 26 47 76 161 290 468 997 2895 30 32 58 94 200 360 582 1240 3603 40 38 68 110 234 421 680 1449 4209 50 43 77 124 264 475 767 1635 4748 60 47 85 137 291 524 846 1804 5239 75 53 95 153 329 591 955 2035 5910

Garden Hose Flow and Time Calculator

Garden Hose Flow Rate and Time The amount of water flow from a garden hose. This assumes a free-flowing hose end (not connected to a sprinkler or something). The minutes to supply a given volume is also determined below. Learn more about the units

Task Force Tips - FAQs

Using a slide chart, table, hose manufacturers data, or other source for hose losses, we find that a flow of 150 GPM corresponds to a hose loss of about 35 psi PER 100 feet of hose. If the hoseline is 150 ft. long, then we would take 1.5 times 35, or 52.5 psi.

Hoses - Water Flow and Pressure Losses

Example - Water Flow through a Hose and Pressure Loss 2 gpm (7.6 liter/min) flows through a 1/2" garden hose with length 82 feet (25 m).From the diagram above the pressure loss per 100 feet can be estimated to 5 psi.The pressure drop in the hose can be

Flow Chart

FM Approved FLOWBUSTER TM FLOW CHART For a given Pitot pressure in PSI, this Flow Chart will determine your Flow in GPM for the specific Nozzle diameter used. Please contact us if you need values for pressures other than those shown. PSI 1-1/8" 1

Hydraulic Hose Sizing - Open Source Ecology

The 50 hp Volkswagen engine is believed to deliver the peak torque at 2700 RPM (needs confirmation) This increased fluid flow requires quick couplers capable of handling more flow. This coupler is rated for 26.4 GPM:

How to Calculate GPM From PSI | Hunker

Interpolating between 35 GPM and 40 GPM, the pressure loss computes to a value between 0.9 and 1.2 PSI loss per 100 feet of pipe. Since 37.5 GPM is halfway between the two flow readings of 35 and 40 GPM, the interpolation will work out to about 0.707 of

How Much Water Does A Pressure Washer Use? (GPM …

So, in addition to PSI, you need to compare GPM as well. They work together to get things clean. Let’s assume a Sun Joe XPX 3000 pressure washer with 1.76 GPM and 2030 PSI competes with Stanley SHP2150 pressure washer with 1.4 GPM with 2150 PSI.

PRESSURE DROP DATA - Jetstream

8MM HOSE FLOW RATE (gpm) 2 4 6 8 1 0 1 2 1 4 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 100’ 50’ 25’ PRESSURE DROP (psi) SERIES 27731, 28082 & 29172 5mm HOSE PRESSURE DROP (psi) 0 Hoses & Lances